Product Center
U2921 LED Checker
VFTest channel:
IF SET Current:
IR Test voltage: DC 0.0V ~ 9.99V
IR Measuring range: 0.0uA ~ 99.9uA
keywords: LCR Meter Capacitance Meter
File:
Category:

Hotline:
product details
- 产品描述
- Technical parameters
- Order information
- Instrument accessories
- Optional accessories
- Video data
-
- Commodity name: U2921 LED Checker
- Commodity ID: 1070438597799858176
VF Measuring range: DC 0.000V ~ 11.40V<BR> VFTest channel:<BR> IF SET Current:<BR> IR Test voltage: DC 0.0V ~ 9.99V<BR> IR Measuring range: 0.0uA ~ 99.9uA
Brief Introduction:
U2922 series LED/diode checker can simultaneously check two-way double channel of LED/diode. CH2 can test the polarity direction of LED or diode; CH1 can test the forward VF value and reverse leakage current IR value of LED or diode. The upper limit and lower limit of VF and IR can be set. The compare results (HI/GO/LO) between the polarity of CH2 (+POL/-POL/NG) and LED VF/IR value of CH1 will be displayed after the end of the test.
Character large screen LCD can simultaneously display two-way value and polarity of VF1, VF2 / IR1, IR2 , which is particularly suitable for LED taping machines.
Features:
■ Two-way double-channel check of LED or diode (only U2922)
■ Precise bicolor LED polarity resolution capability (only U2922)
■ Selectable common anode or common cathode test mode (only U2922)
■ Diode geminate transistors can be tested (only U2922)
■ Up to 100mA forward test current (only U2922)
■ Simultaneous polarity test in two channels, forward VF1, VF2
■ Simultaneous test of LED/diode, reverse IR1, IR2
■ Large LCD screen and complete information display
■ High speed measurement: only 22ms
■ Easy operation
■ Parameter setup without loosing after shutdown
■ Standard Handler interface
■ Apply to dual LED, high speed screening and taping of diode
General Specifications:
Temperature & Humidity 0°C-40°C, ≤90%RH Power Requirements Voltage 198V - 242V Frequency 50Hz Power ≤30 VA Dimension(W×H×D) 250mm×90mm×270mm Weight appro. 3.5kg -
Range Accuracy VF1/VF2 Test current (IF SET) U2922 DC 0.1mA ~ 99.9mA ±0.1mA±2 digit U2921B DC 0.1mA ~ 9.99mA Measurement range of VF value DC 0.000V ~ 11.40V ±0.5% of F.S ±1 digit Lower limit range of VF1/VF2 0.00V ~ 11.40V Upper limit range of VF1/VF2 0.00V ~ 11.40V Test voltage of VR DC 0.0V ~ 9.99V ±0.1V ±2 digit Measurement range of IR1/IR2 0.0uA ~ 99.9uA ±0.5% of F.S ±0.1uA Lower limit range of IR1/IR2 0.0uA ~ 99.9uA Upper limit range of IR1/IR2 0.0uA ~ 99.9uA -
U2921 Double-channel LED Checker
-
U26002A Two-terminal test clip
-
Recommended products
AC test: 0.05kV-5kV ±(2% reading+5 digits)(50、60Hz selectable)
DC test: 0.05kV-6kV ±(2% reading+5 digits)
Output channel: 0.05kV – 1kV ±(1.0% reading+2V)
Grouping test function: AC
Interface configuration: PLC,RS232C
Basic accuracy: 0.1%
Test level: 0.6Vrms
Test speed: 10meas/sec(Fast), 5meas/sec(Med), 2meas/sec(Slow)
Internal bias: -----
Output Impedance: 100 Ω
Basic accuracy: 0.1%
Test level: 0.6Vrms
Test speed: 10meas/sec(Fast), 5meas/sec(Med), 2meas/sec(Slow)
Internal bias: -----
Output Impedance: 100 Ω
Basic accuracy: 0.1%
Test level: 0.6Vrms
Test speed: 10meas/sec(Fast), 5meas/sec(Mid), 2meas/sec(Slow)
Internal bias: -----
Output Impedance: 100 Ω