Product Center
U2816B Precision LCR Meter
Basic accuracy: 0.05%
Test level: 10mV – 2V,Resolution:1mV
Test speed: Fast: 65, Med: 10, Slow: 5 (meas/sec)
Internal bias: no
Output Impedance: 10Ω, 30Ω, 100Ω
keywords: LCR Meter Capacitance Meter
File:
Category:

Hotline:
product details
- 产品描述
- Technical parameters
- Order information
- Instrument accessories
- Optional accessories
- Video data
-
- Commodity name: U2816B Precision LCR Meter
- Commodity ID: 1070404818272145408
Test frequency: 50Hz – 200kHz, 37 typical frequency<BR> Basic accuracy: 0.05%<BR> Test level: 10mV – 2V,Resolution:1mV<BR> Test speed: Fast: 65, Med: 10, Slow: 5 (meas/sec)<BR> Internal bias: no<BR> Output Impedance: 10Ω, 30Ω, 100Ω
Brief Introduction:
U2816 Series Precision LCR Meter is a new generation of impedance test equipment with high accuracy, wide measurement range and six digits resolution. Being possessed with test frequency up to 200kHz, test voltage of 10mV-2V, built-in typical DC bias and -10V-10V DC voltage source output, it can meet all requirements for measuring components and materials and provide guarantees for production line quality assurance, incoming inspection and laboratory precision measurements. Otherwise, the Handler, RS232C and GPIB interfaces as well as improved command system provided by the instrument make it easier to build the test system.
Features:
■ Simultaneously display of four different parameters with flexible combinations
■ AC and DC parameters can be measured simultaneously without interference; self-demagnetization
■ High speed and efficiency measurement: Max. 65 meas / sec (with display)
■ Built-in bias voltage: -5V- + 5V; resolution: 1mV
■Support DC source output: continuously adjustable independent voltage source -10V ~ 10V, resolution of 2.5mV, low noise
■ Auto DUT trigger function: the DUT can be measured once be trigger and the measurement results and discrimination will be displayed.
■ Flexible limit comparator: support tolerance mode, sequence mode and parameter exchange
■ Rapid and easy determination of Pass/Fail through multi-parameter test function
■ Powerful list sweep function: mixed scanning of various excitation source and display of different parameters; also support multiple-channel scanners of devices
■ New graphical scanning functions: frequency / level / bias / DC source make nuanced analysis of elements
■ Complete user correction function: up to 32 dot frequency correction; can be applied to multi-channel scanning amendment for higher measurement consistency and repeatability
■ Rich communication interfaces: RS232C / USB-CDC / USB-TMC / HANDLER / GPIB
■ Multiple USB storage modes: CSV and TXT format for storing test data, BMP, PNG, GIF formats for stored on-screen images, U disk storage / recall setup files, U disk firmware upgrade
■ Storage / recall of Parameters: real-time storage of all parameters without losing after shutdown; supporting internal storage of 100 groups, external storage and recalling of 500 groups
General Specifications:
Temperature & Humidity 0°C-40°C, ≤90%RH Power Requirements Voltage 99V - 242V Frequency 47.5Hz-63Hz Power ≤ 20 VA Dimension(W×H×D) 350mm×120mm×360mm Weight approx. 3.5kg -
Measurement function Test parameter |Z|,C,L,R, X, |Y|,B,G,D,Q,θ,DCR(option) Basic Accuracy 0.05% 0.05% Measuring speed Fast: 65, Med: 10, Slow: 5 (meas/sec) Equivalent circuit Series and Parallel Ranging mode Auto, Hold Trigger mode Internal, Manual,Auto, External and Bus Correction Open / short / load, 32 dot frequency correction Graphic Scanning (Optional) Frequency, level, bias voltage / current, DC source (Only U2816A is optional) List sweep 10 points frequency, level, bias voltage / current, DC source Monitor 480 * 272, 5-inch TFT color screen Memory Internal:100 groups,External:500 groups(U-disk) Test signal Test frequency U2816A 50Hz – 200kHz, Resolution:1mHz U2816B 50Hz – 200kHz, 37 typical frequency Output Impedance 10Ω, 30Ω, 100Ω Test level 10mV – 2V,Resolution:1mV ALC function 10mV – 1V (no in U2816B) Internal DC bias source U2816A -5V- +5V; resolution:1mV U2816B no Built-in DC source (Option) -10V - +10V; resolution: 2.5mV Measurement display range |Z|, R,X 0.01mΩ - 99.9999MΩ |Y|, G, B 0.0001uS – 999.999S C 0.00001pF – 999.999mF L 0.00001µH – 99.9999kH D 0.00001 - 9.99999 θ(Deg) -179.9° – 179.9° θ(Rad) -3.14159 – 3.14159 Q 0.01 - 99999.9 Δ% -999.99% - 999.99% DCR 1mΩ - 99.9999MΩ (only U2816A is optional) Comparator and interface Comparators 10 bins, BIN0 - BIN9, NG, AUX PASS / FAIL LED display Interfaces RS232C/USB-HOST/USB-CDC/ USB-TMC/HANDLER/GPIB(Options)/SCNANER(Options) -
U2816B Precision LCR Meter
-
U26005 Four-terminal test fixture U26011 Four-terminal Kelvin test cable U26010 Gilded shorting plate
-
U26006 轴向元件测试夹具(与U26005配合使用)
U26008 SMD 元件测试夹具
U26009 SMD 测试钳
U10401 DCR测量板
U10501 1A可编程直流偏置电流源
U10502 100mA可编程直流偏置电流源
U10503 可编程直流电压源, -10V - +10V
U10301 GPIB接口板
U10601 SCANNER接口板
U10201 数据采集软件
Recommended products
AC test: 0.05kV-5kV ±(2% reading+5 digits)(50、60Hz selectable)
DC test: 0.05kV-6kV ±(2% reading+5 digits)
Output channel: 0.05kV – 1kV ±(1.0% reading+2V)
Grouping test function: AC
Interface configuration: PLC,RS232C
Basic accuracy: 0.1%
Test level: 0.6Vrms
Test speed: 10meas/sec(Fast), 5meas/sec(Med), 2meas/sec(Slow)
Internal bias: -----
Output Impedance: 100 Ω
Basic accuracy: 0.1%
Test level: 0.6Vrms
Test speed: 10meas/sec(Fast), 5meas/sec(Med), 2meas/sec(Slow)
Internal bias: -----
Output Impedance: 100 Ω
Basic accuracy: 0.1%
Test level: 0.6Vrms
Test speed: 10meas/sec(Fast), 5meas/sec(Mid), 2meas/sec(Slow)
Internal bias: -----
Output Impedance: 100 Ω
Online Message