Product Center
Current position:
Homepage
/
/
/
U2829B Precision LCR Meter

Product

Contact

Address:B2, Building 23, New Dynamic Business Center, No. 1, Qingyang North Road, Tianning District, Changzhou

Tel:0519-85505199

Fax:0519-85505169

E-mail:sales@eucol.com.cn

Conatct:Mr. Jacky Bao

U2829B Precision LCR Meter

Test frequency: 20Hz–500kHz
Basic accuracy: 0.05%
Test level: 5 mV-2V(standard);5mV–10V(enhanced)
Test speed: Fast: 9, Med: 67, Slow:187 (ms/time) Internal bias: -5V – +5V
Output Impedance: 10Ω/CC , 25Ω ,50Ω , 100Ω

Buy

yg     yg

零售价
0.0
市场价
0.0
浏览量:
1000
产品编号
Category
LCR Meter
数量
-
+
库存:
0
1
Details
Technical parameters
Order information
Instrument accessories
Optional accessories
Video data

Brief Introduce:

U2829 Series LCR Meter is a new generation of impedance test equipment with high accuracy, wide measurement range and six digits resolution. Being possessed with test frequency of 20Hz-1MHz, test voltage of 5mV~10V and built-in typical DC bias, it can meet all requirements for measuring components and materials and provide guarantees for production line quality assurance, incoming inspection and laboratory precision measurements. Otherwise, the Handler, RS232C and GPIB interfaces as well as improved command system provided by the instrument make it easier to build the test system.

Features:

■ 7-inch 16:9 TFT LCD display and resolution of 800*480

■ Max. Test frequency: 1MHz; resolution: 1mHz

■ Max. Test speed: 9ms/time

■ Test signal level: 5 mV-2V(standard);5mV – 10V(enhanced)

■ Basic Accuracy:0.05%

■ Continuous curve scanning/Graphic analysis function

■ Open/short/load correction

■ Optional ±100mA, ±10V bias voltage source, 0–1A bias current

■ Internal storage: 100 groups; External storage and recall: 500 groups

■ Test data and screen graphs can be saved to U-disk in several formats

■ Multiple file search modes: fuzzy search, accurate search and bar-code search

■ Abundant interfaces:RS232C, USBTMC, USBCDC, HANDLER, GPIB

■Be equipped with BNC trigger to realize external foot switch connection In accordance with LXI standard and rapid building of test system

General Specifications:

Temperature & Humidity 0°C-40°C,  ≤90%RH
Power Requirements Voltage 198V-242V or 99V-121V
Frequency 47.5Hz-63Hz
Power ≤ 80 VA
Dimension(W×H×D) 400mm×132mm×350mm
Weight approx. 10.0kg
未找到相应参数组,请于后台属性模板中添加
System Specifications
Test Frequency and Function U2829A 20Hz – 300kHz Continuous frequency,resolutaion:1mHz
U2829B 20Hz – 500kHz
U2829C 20Hz – 1MHz
Measurement function
LCR Test parameter |Z|, |Y|, C, L, X, B, R, G, D, Q, θ ,DCR
Basic Accuracy 0.05%
Measuring speed(≥10kHz) Fast: 9, Med: 67, Slow:187 (ms/time)
Equivalent circuit Series and Parallel
Ranging mode Auto, Hold
Trigger mode Internal, Manual, External and Bus
Average numbers 1—255
Delay time 0—60s, 1ms step
Correction Open/short, dot frequency, full frequency, load
List sweep 40 points frequency, level, bias voltage/current
Graphic Scanning Frequency, level, bias voltage / current
Test signal
Test signal level 5 mV-2V(standard);5mV – 10V(enhanced), Auto level range:5 mV-1 V  Accuracy:5% , Resolution:1mV
Output Impedance 10Ω/CC , 25Ω ,50Ω , 100Ωoption
DC bias (internal) -5V – +5V (continuous),Accuracy:1%
Measurement display range
|Z|, R, X 0.00001 Ω — 99.9999 MΩ
DCR 0.00001 Ω — 99.9999 MΩ
|Y|, G, B 0.00001µS — 99.9999 S
C 0.00001 pF — 9.9999 F
L 0.00001 µH — 99.9999 kH
D 0.00001 — 9.99999
Q 0.00001 — 99999.9
θ (DEG) -179.999º — 179.999 º
θ (RAD) -3.14159 — 3.14159
Δ% -999.999% — 999.999%
Other
Comparator 10 bins, bin counter
Memory Internal storage: 100 groups,External storage: 500 groups
Interface RS232C,USBTMC, USBCDC, Handler, GPIB(option)

U2829B Precision LCR Meter

U26005 Four-terminal test fixture U26011 Four-terminal Kelvin test cable U26010 Gilded shorting plate

U26006 轴向元件测试夹具(与U26005配合使用)

U26008 SMD元件测试夹具

U26009 SMD测试钳

U10502 100mA/10V 偏流板

U10501 1A DC偏流板

U10301 GPIB接口板

Related Products

 U2831 LCR Meter
U2831 LCR Meter
Test frequency: 50Hz – 100kHz, resolution:10mHz
Basic accuracy: 0.05%
Test level: 10mV—2.0V,resolution:10mV 100uA-20mA
Test speed: Fast: 12.5ms, Med: 83ms, Slow: 167ms(meas/sec)
Internal bias: 0V —— ±5V / 0mA —— ±20mA
Output Impedance: 30Ω, 50Ω, 100Ω
 U2826A High-frequency LCR Meter
U2826A High-frequency LCR Meter
Test frequency: 20Hz – 2MHz, resolution:10mHz
Basic accuracy: 0.1%
Test level: 10mV~5V,resolution:10mV
Test speed: Fast: 180, Med: 25, Slow: 5 (meas/sec)
Internal bias: -5V ~ +5V,resolution: 1mV
Output Impedance: 10Ω, 30Ω, 50Ω, 100Ω
 U2815 LCR Meter
U2815 LCR Meter
Test frequency: 20Hz – 1MHz,resolution:10mHz
Basic accuracy: 0.1%
Test level: 10mV ~ 5V,resolution:10mV
Test speed: Fast: 120, Med:25, Slow: 5 (meas/sec)
Internal bias: -5V – +5V, resolution: 1mV
Output Impedance: 10Ω, 30Ω, 50Ω, 100Ω
 U2829A Precision LCR Meter
U2829A Precision LCR Meter
Test frequency: 20Hz–300kHz
Basic accuracy: 0.05%
Test level: 5 mV-2V(standard);5mV–10V(enhanced)
Test speed: Fast: 9, Med: 67, Slow:187 (ms/time)
Internal bias: -5V – +5V
Output Impedance: 10Ω/CC , 25Ω ,50Ω , 100Ω
 U2829B Precision LCR Meter
U2829B Precision LCR Meter
Test frequency: 20Hz–500kHz
Basic accuracy: 0.05%
Test level: 5 mV-2V(standard);5mV–10V(enhanced)
Test speed: Fast: 9, Med: 67, Slow:187 (ms/time) Internal bias: -5V – +5V
Output Impedance: 10Ω/CC , 25Ω ,50Ω , 100Ω
 U2829C Precision LCR Meter
U2829C Precision LCR Meter
Test frequency: 20Hz–1MHz
Basic accuracy: 0.05%
Test level: 5 mV-2V(standard);5mV–10V(enhanced)
Test speed: Fast: 9, Med: 67, Slow:187 (ms/time)
Internal bias: -5V – +5V
Output Impedance: 10Ω/CC , 25Ω ,50Ω , 100Ω
 U2818 Precision LCR Meter
U2818 Precision LCR Meter
Test frequency: 20Hz – 300kHz
Basic accuracy: 0.05%
Test level: 5mV – 2V, resolution:1mV;100uA – 100mA, resolution:1uA
Test speed: Fast: 65, Med: 10, Slow: 5 (meas/sec)
Internal bias: Voltage mode:-5V -+5V,1mV steps,Current Mode:-50mA – 50mA , 20uA steps Output Impedance: 10Ω, 30Ω, 100Ω
 U2819 Precision LCR Meter
U2819 Precision LCR Meter
Test frequency: 20Hz – 200kHz
Basic accuracy: 0.05%
Test level: 5mV – 2V,resolution:1mV;100uA – 100mA, resolution:1uA
Test speed: Fast: 65, Med: 10, Slow: 5 (meas/sec)
Internal bias: Voltage mode:-5V -+5V,1mV steps;Current Mode:-50mA – 50mA , 20uA steps
Output Impedance: 10Ω, 30Ω, 100Ω
 U2816A Precision LCR Meter
U2816A Precision LCR Meter
Test frequency: 50Hz – 200kHz, Resolution:1mHz
Basic accuracy: 0.05%
Test level: 10mV – 2V,Resolution:1mV
Test speed: Fast: 65, Med: 10, Slow: 5 (meas/sec) Internal bias: 5V- +5V,Resolution:1mV;U2816B
Output Impedance: 10Ω, 30Ω, 100Ω

Feedback

Username used for comment:
客户留言
Description:
验证码

yg

Address: B2, Building 23, New Dynamic Business Center, No. 1, Qingyang North Road, Tianning District, Changzhou

Tel:0519-85505199    Fax:0519-85505169

E-mail:sales@eucol.com.cn

CODE

WeChat

CODE

Add WeChat

Changzhou Eucol Electronic Technology Co.,Ltd    苏ICP备14031197号 Powerd by:300.cn Changzhou Support IPv6